IICL-6 Inspection Criteria

 

iicl logoThe Institute of International Container Lessors (IICL) has revised its inspection criteria and processes for dry van containers, known as "IICL 6", which was implemented on a worldwide basis on 1 August 2016.

IICL 6 is the result of work by the IICL Technical Committee (TC) to update and harmonize several inspection criteria and processes that had developed over recent years. Benefits of the IICL 6 standard include the simplification and efficiency improvement of procedures for container inspections performed at container depots around the world.

Visitors to IICL 6 site will learn about the new inspection criteria through the following NEW Inspection Overview Video, technical and measurement techniques bulletins.

Links to the IICL's publication tool store and to the annual IICL Container Inspector Certification Examination and Courses are also provided for your ready access.

Dry Van Inspection Comparison Table

 

Component

IICL 5

CIC

IICL 6

Reason/Comments

           

1

Flat bar top side rail

25 mm

30 mm

30 mm

Same as IICL5 for tube top side rail

           

2

Front headers

25 mm

40 mm

35 mm

Same as rear

headers and other dents

           

3

Rear headers

35 mm

40 mm

35 mm

Same as all other dents

           

4

Front & rear
corner posts

25 mm single dent. If 2 dents or more, 15 mm dent.

20 mm

Any number of dents.

20 mm

Any number of dents.

Reduces repairs without

compromising structure

           

5

All side & front panels

35 mm dents (in or out)

35 mm internal cube intrusion

35 mm internal cube intrusion

Ease of measurement

           

6

Door panels

35 mm dents (in or out)

35 mm internal cube intrusion

35 mm internal cube intrusion

Ease of measurement

           

7

All roof panels

35 mm dents (in or out)

50 mm internal cube intrusion

40 mm internal cube intrusion

Reasonable internal cube intrusion, minimizes

commercial concern

           

8

Flooring height difference

5 mm

10mm

5 mm

 
           

9

End frame (ISO tolerance)

As per below:

As per below:

As per below:

 

9. A

Corner posts

ISO + 5 mm all faces (5mm beyond corner fitting end face)

ISO + 5 mm on end face

ISO + 5 mm on end face

No difference

ISO + 5 mm all faces (5mm beyond corner fitting side face)

ISO + 10 mm on side faces

ISO + 10 mm on side faces

(10mm beyond corner fitting side face)

No vessel stowage operational issues with 10 mm on side faces

9. B

Doors, headers, sills

ISO + 5 mm on end face

(5mm beyond corner fitting end face)

ISO + 5 mm on end face

ISO + 5 mm on end face

No difference

 

Dry Van Inspection Comparison Table (Continued)

 

Component

IICL 5

CIC

IICL 6

Reason/Comments

           

10

Entire container (ISO tolerance)

As per below:

As per below:

As per below:

 

10. A

Side panels - outward

ISO + 10 mm

(10mm beyond corner fitting side face)

30 mm measured in an outward direction from an outward recessed corrugation

30 mm measured in an outward

direction from an outward recessed corrugation

Equivalent to ISO +

20 mm measured in an outward direction from an outside recessed

corrugation. No vessel stowage operational issues at ISO + 20 mm

10. B

Roof panels - upward

ISO + 4 mm

(4mm beyond corner fitting top face)

50 mm measured in an upward direction from the upper faces of the top side rails to an outward recessed corrugation

40mm measured in an upward direction from the upper

faces of the top side rails to an outward recessed

corrugation

Standardize roof dent in/out criteria

10. C

Front panel – outward

ISO + 5 mm

(5mm beyond corner fitting end face)

15 mm measured in an outward direction from an outward recessed corrugation

15 mm measured in an outward

direction from an outward recessed corrugation

 

NOTE: All other component criteria to remain unchanged from IICL 5 inspection tables.

 

文本框: IICL 6 Dry Van Inspection Table Revisions

Component

Component Revisions

Reason/Comments

 

Table Reference

     
         

1

Flat bar top side rail

30 mm - Table 5.1

Same as IICL5 for tube top rail

 
         

2

Front headers

35 mm - Table 5.1

Same as rear headers and other dents

 
         

3

Rear headers

35 mm - Table 5.1

Same as all other dents

 
         

4

Front & rear corner posts

20 mm - Table 5.2 Any number of dents.

Reduces repairs without compromising structure

 
         

5

All side & front panels

35 mm internal cube intrusion - Table 5.3

Ease of measurement

 
         

6

Door panels

35 mm internal cube intrusion - Table 5.4

Ease of measurement

 
         

7

All roof panels

40 mm internal cube intrusion - Table 5.5

Reasonable internal cube intrusion, minimizes commercial concern

 
         

8

Flooring height difference

5 mm - Table 5.6

   
         

9

End frame (ISO tolerance)

As per below - Table 5.8

   

9. A

Corner posts

ISO + 5 mm on end face

(5mm beyond corner fitting end face)

No difference

 

ISO + 10 mm on side faces (10mm beyond corner fitting side face)

No vessel stowage operational issues with

10 mm on side faces

 

9. B

Doors, headers, sills

ISO + 5 mm on end face

(5mm beyond corner fitting end face)

No difference

 
         

10

Entire container (ISO tolerance)

As per below - Table 5.8

   

10. A

Side panels - outward

30 mm measured in an outward direction from an outward recessed corrugation

Equivalent to ISO + 20 mm measured in an outward direction from an outside recessed corrugation. No vessel stowage

operational issues at ISO + 20 mm

 

10. B

Roof panels - upward

40mm measured in an upward direction from the upper faces of the top side rails to an outward recessed corrugation

Standardize roof dent in/out criteria

 

10. C

Front panel – outward

15 mm measured in an outward direction from an outward

recessed corrugation

   

NOTE: All other component criteria to remain unchanged from IICL 5 inspection tables.

 

星期五, 08 9月 2017 Posted in Container Inspection & Repair

logo

Gateway Container International Limited, specialized in container trading, and container one way leasing . The main service area is Eurasia.

Get In Touch

RM.419-421, Tianda Business Centre, No.203, Moling Road, Jing'an District, Shanghai, China. P.C.:200070

+86(21) 6393-1256

  sales@gatewaycontainer.com

 www.gatewaycontainer.com

Join Our Community

Sign up to receive email for the latest information.